Liquid flow analysis and thermal simulations for a lithium Ion battery module
Following are the goals of this project that needs to be achieved through software simulations: Smooth flow of coolant within the thermal management loop without high pressure build up. Pressure should not exceed 110000 pascals within any thermal management loop component at any given point of time. Cell temperature within the battery module to stay within 20-25C no matter outside temperature levels. Flow rate of coolant should not exceed 1.6litres/minute at any given point of time.